Testing

See below extremegreen™ Magnesium Oxide Board ASTM testing certification

ASTM Test NumberTest Description
ASTM C1185Flexural Strength (Modulous of Rupture)
ASTM D2718Shear Strength
ASTM C1185Flexural Strength Degredation due to Construction Site Exposure
ASTM C1185Flexural Strength Degredation due to Freeze/Thaw (300 Freeze/Thaw Cycles)
ASTM C1185Flexural Strength Degredation due to Extreme Temperatures
ASTM C1185Flexural Strength Degredation due to Thermal Ageing
ASTM C1185Flexural Stregnth Degredation due to UV Exposure
ASTM 1185Flexural Strength Degredation due to Water Exposure
ASTM C666-03Resistance to Freeze/Thaw (300 Freeze/Thaw Cycles)
DOC PS-2Linear Expansion due to Humidity
ASTM E228Linear Expansion due to Temperature Differential
ASTM C1185Density / Specific Gravity
ASTM C1185Density / Specific Gravity (68º F / 65% RH)
ASTM C1185Moisture Content
ASTM D3500Axial Tension
ASTM D3501Axial Compression
ASTM D1037Fastener Withdrawal Capacity
ASTM D1037Lateral Fastener Capacity
ASTM D1037Fastener Head Pull-Through
AWPA E12Fastener Corrosivity
ASTM D1037Fastener Withdrawal Resistance Loss due to Water Exposure
ASTM D1037Fastener Lateral Resistance Loss due to Water Exposure
ASTM D1037Fastener Head Pull-Through Loss due to Water Exposure
ASTM D6815Long Duration Loads / Creep
ASTM G21Standard Test to Determine Building Material’s Resistance to Mold and Funghi
“ASTM E84-15a, ASTM E84-16
(UL 723, UBC 8-1, NFPA 255)”
Surface Burning Characteristics of Building Materials
“ASTM E119-15
(ANSI / UL 263)”
1-Hour Fire-resistant Non-Load Bearing Wall Assembly – Steel
“ASTM E119-12a
(ANSI / UL 263)”
2-Hour Fire-resistant Non-Load Bearing Wall Assembly – Steel
“ASTM E119-12a
(ANSI / UL 263)”
2-Hour Fire-resistant Non-Load Bearing Wall Assembly – Wood
DOC PS-2Voluntary Product Standard – Uniform Load Test for Subflooring 16″ o.c.
DOC PS-2Voluntary Product Standard – Uniform Load Test for Subflooring 24″ o.c.
Engineering EvaluationL/240, L/360, L/480 Defelction Values for use as Sublfooring
Engineering EvaluationMaximum Alloawable Live Loads for use as Subflooring
ASTM E90“Accoustical Performance – Steel C-Channel Floor/Ceiling Assembly – Bare
extremegreen™ Subfloor / extremegreen™ Ceiling”
ASTM 492“Accoustical Performance – Steel C-Channel Floor/Ceiling Assembly – Bare
extremegreen™ Subfloor / extremegreen™ Ceiling”
ASTM E90“Accoustical Performance – Steel C-Channel Floor/Ceiling Assembly – Bare
extremegreen™ Subfloor / extremegreen™ Ceiling”
ASTM 492“Accoustical Performance – Steel C-Channel Floor/Ceiling Assembly – LVT
extremegreen™ Subfloor / extremegreen™ Ceiling”
ASTM E90“Accoustical Performance – Steel C-Channel Floor/Ceiling Assembly – Carpet
extremegreen™ Subfloor / extremegreen™ Ceiling”
ASTM 492“Accoustical Performance – Steel C-Channel Floor/Ceiling Assembly – Carpet
extremegreen™ Subfloor / extremegreen™ Ceiling”
ASTM E90“Accoustical Performance – Wood Open Web Truss Floor/Ceiling Assembly – Bare. extremegreen™ Subfloor / extremegreen™ Ceiling”
ASTM 492“Accoustical Performance – Wood Open Web Truss Floor/Ceiling Assembly – Bare. extremegreen™ Subfloor / extremegreen™ Ceiling”
ASTM E90“Accoustical Performance – Wood Open Web Truss Floor/Ceiling Assembly – LVT. extremegreen™ Subfloor / extremegreen™ Ceiling”
ASTM 492“Accoustical Performance – Wood Open Web Truss Floor/Ceiling Assembly – LVT. extremegreen™ Subfloor / extremegreen™ Ceiling”
ASTM E90“Accoustical Performance – Wood Open Web Truss Floor/Ceiling Assembly – Carpet. extremegreen™ Subfloor / extremegreen™ Ceiling”
ASTM 492“Accoustical Performance – Wood Open Web Truss Floor/Ceiling Assembly – Carpet. extremegreen™ Subfloor / extremegreen™ Ceiling”
ASTM E90“Accoustical Performance – Steel C-Channel Floor/Ceiling Assembly – Bare
extremegreen™ Subfloor / Sheetrock® Ceiling”
ASTM 492“Accoustical Performance – Steel C-Channel Floor/Ceiling Assembly – Bare
extremegreen™ Subfloor / Sheetrock® Ceiling”
ASTM E90“Accoustical Performance – Steel C-Channel Floor/Ceiling Assembly – LVT
extremegreen™ Subfloor / Sheetrock® Ceiling”
ASTM 492“Accoustical Performance – Steel C-Channel Floor/Ceiling Assembly – LVT
extremegreen™ Subfloor / Sheetrock® Ceiling”
ASTM E90“Accoustical Performance – Steel C-Channel Floor/Ceiling Assembly – Carpet
extremegreen™ Subfloor / Sheetrock® Ceiling”
ASTM 492“Accoustical Performance – Steel C-Channel Floor/Ceiling Assembly – Carpet
extremegreen™ Subfloor / Sheetrock® Ceiling”
ASTM E90“Accoustical Performance – Wood Open Web Truss Floor/Ceiling Assembly – Bare. extremegreen™ Subfloor / Sheetrock® Ceiling”
ASTM 492“Accoustical Performance – Wood Open Web Truss Floor/Ceiling Assembly – Bare. extremegreen™ Subfloor / Sheetrock® Ceiling”
ASTM E90“Accoustical Performance – Wood Open Web Truss Floor/Ceiling Assembly – LVT. extremegreen™ Subfloor / Sheetrock® Ceiling”
ASTM 492“Accoustical Performance – Wood Open Web Truss Floor/Ceiling Assembly – LVT. extremegreen™ Subfloor / Sheetrock® Ceiling”
ASTM E90“Accoustical Performance – Wood Open Web Truss Floor/Ceiling Assembly – Carpet. extremegreen™ Subfloor / Sheetrock® Ceiling”
ASTM 492“Accoustical Performance – Wood Open Web Truss Floor/Ceiling Assembly – Carpet. extremegreen™ Subfloor / Sheetrock® Ceiling”
ASTM E90“Accoustical Performance – 1-Hour Fire-resistant Non-Load Bearing Wall Assembly – Steel. extremegreen™ Both Sides of Wall Assembly”
ASTM E90“Accoustical Performance – 2-Hour Fire-resistant Non-Load Bearing Wall Assembly – Steel. extremegreen™ Both Sides of Wall Assembly”
ASTM E90“Accoustical Performance – 2-Hour Fire-resistant Non-Load Bearing Wall Assembly – Wood. extremegreen™ Both Sides of Wall Assembly”
ASTM E90“Accoustical Performance – 2-Hour Fire-resistant Load Bearing Separation Shaft Wall Assembly – Wood. extremegreen™ Throughout Wall Assembly”
ASTM E90“Accoustical Performance – 2-Hour Fire-resistant Load Bearing Separation Wall Assembly – Wood. extremegreen™ Both Sides of Wall Assembly”
BS 5268-6.1:1996Racking Strength – Timber Frame Wall Assemblies
BS EN 1995-1:2004+A2:2014Racking Strength – Timber Frame Wall Assemblies
EN 13501-1 Class A1Class A1 Fire Rated
BS EN 12467:2012Physical Properties
BS EN 594 2011Racking Strength – Timber Frame Wall Assemblies
BS EN 1995-1Eurocode 5: Design of Timber Structures
BS EN 5268-6.1Structural Use of Timber. Code of Practice for Timber Frame Walls
EN ISO 1716:2010Reaction to Fire
BS EN ISO 1182:2010Non-Combustible
EN 717-3-1996Dangerous Sunstances – No Formaldehyde, Asbetos or Radioactive Material
ISO 6980Dangerous Sunstances – No Formaldehyde, Asbetos or Radioactive Material
ISO 6892-1998Tensile Strength